Cui Hua
- Professor
- Supervisor of Doctorate Candidates
- Supervisor of Master's Candidates
- Name (English):Hua Cui
- Name (Pinyin):Cui Hua
- E-Mail:
- Business Address:环境资源楼-339
- Contact Information:0551-3600730
- Degree:Dr
- Professional Title:Professor
- Teacher College:Chemistry and Materials Science
Contact Information
- Fax:
- OfficePhone:
- Email:
- Paper Publications
Nanoparticle-based electrochemiluminescence immunosensor with enhanced sensitivity for cardiac troponin I using N-(aminobutyl)-N-(ethylisoluminol)-functionalized gold nanoparticles as labels
Release time:2021-08-02 Hits:
- DOI number:10.1016/j.bios.2011.05.022
- Journal:Biosens. Bioelectron.
- Abstract:A novel nanoparticle-based electrochemiluminescence (ECL) immunosensor was designed for highly sensitive and selective detection of human cardiac troponin I (cTnI), an important Acute Myocardial Infarction (AMI)-related biomarker, by using N-(aminobutyl)-N-(ethylisoluminol)-functionalized gold nanoparticles (ABEI-AuNPs) as labels. ABEI-AuNPs were successfully synthesized via a simple seed growth method. A great number of luminescence molecules ABEI as stabilizers were coated on the surface of the AuNPs, which exhibited better ECL activities than previously reported luminol functionalized gold nanoparticles. ABEI-AuNPs were used as new ECL labels to build bio-probes by conjugation with secondary antibodies, which showed good ECL activity, immunological activity, and stability. Another kind of AuNPs functionalized with streptavidin was modified on the electrode surface for biotinylated antibodies capture through the specific interaction of biotin/streptavidin and enhancing the electrical connectivity. By combining with the novel ECL labels and amplification of AuNPs and biotin–streptavidin system, a high sensitive sandwich-type electrochemiluminescence immunoassay was developed for detecting human cTnI with a low detection limit of 2 pg/mL. The immunosensor showed good precision, acceptable stability and reproducibility and could be used for the detection of cTnI in real samples, which was of great potential application in clinical analysis. Importantly, the sensitive detection would have far more diagnostic value than would absolute measurements during the early stage of AMI.
- Co-author:田大勇,杨迪,卞智萍
- First Author:沈雯
- Indexed by:Journal paper
- Correspondence Author:Hua Cui
- Discipline:Natural Science
- Document Type:J
- Volume:27
- Issue:1
- Page Number:18-24
- Translation or Not:no
- Date of Publication:2011-09-15
- Included Journals:SCI
- Links to published journals:https://www.sciencedirect.com/science/article/pii/S0956566311003198