Cui Hua
- Professor
- Supervisor of Doctorate Candidates
- Supervisor of Master's Candidates
- Name (English):Hua Cui
- Name (Pinyin):Cui Hua
- E-Mail:
- Business Address:环境资源楼-339
- Contact Information:0551-3600730
- Degree:Dr
- Professional Title:Professor
- Teacher College:Chemistry and Materials Science
Contact Information
- Fax:
- OfficePhone:
- Email:
- Paper Publications
Electrochemiluminescence bioassay for thrombin based on dynamic assembly of aptamer, thrombin and N-(aminobutyl)-N-(ethylisoluminol) functionalized gold nanoparticles
Release time:2021-07-23 Hits:
- Impact Factor:6.215
- DOI number:10.1016/j.electacta.2014.01.098
- Journal:Electrochimica Acta
- Abstract:An electrochemiluminescence (ECL) bioassay was developed for the sensitive and selective detection of thrombin, based on dynamic interaction of aptamer, thrombin and N-(aminobutyl)-N-(ethylisoluminol) (ABEI) functionalized gold nanoparticles (ABEI-AuNPs). Gold nanoparticles by citrate reduction (AuNPs) were firstly assembled onto a gold electrode through 1, 3-propanedithiol, which was further connected with thiolated DNA capture probe. Then biotinylated DNA aptamer probe was assembled onto the modified electrode through the hybridization between capture probe and aptamer probe. After adding target thrombin, aptamer could bind tightly to target molecules to form a tertiary target–aptamer complex with a binding constant greater than DNA duplex, leading to partial extrication of biotinylated DNA aptamer probe from the surface of electrode. Finally, the ABEI-AuNPs coated with streptavidin (SA) were connected with the biotinylated DNA aptamer probe left after specific binding with thrombin to form the aptamer-ABEI-AuNPs complex on the electrode. When a double-step potential was applied to the electrode, an ECL signal was generated and recorded. The decrease of ECL signal was in proportion to the concentration of thrombin over the range of 1.0 × 10−12–1.0 × 10−9 M with a detection limit of 3.8 × 10−13 M. The proposed bioassay for the determination of thrombin is sensitive, specific, simple and fast. Finally, being challenged in real blood sample, the proposed bioassay was confirmed to be a good prospect for the detection of thrombin. This work provides a new way to design aptamer-based protocols for the determination of biologically important substances.
- First Author:于秀霞
- Indexed by:Journal paper
- Correspondence Author:Hua Cui
- Document Code:000335424300019
- Discipline:Natural Science
- Document Type:J
- Volume:125
- Page Number:156-162
- ISSN No.:0013-4686
- Translation or Not:no
- Date of Publication:2014-04-10
- Included Journals:SCI
- Links to published journals:https://www.sciencedirect.com/science/article/pii/S0013468614001777